Laminarteko hausturaren I/II modu mistoa aztertzeko saiakuntza konfigurazio berri bat

  1. Ana Boyano
  2. Juan Luis Osa
  3. Unai Fernandez-Gamiz
  4. Leyre Torre
  5. Faustino Mujika
Journal:
Ekaia: Euskal Herriko Unibertsitateko zientzi eta teknologi aldizkaria

ISSN: 0214-9001

Year of publication: 2018

Issue Title: 2015-2016 Euskal Tesien 15 pasarte

Issue: 1

Pages: 37-50

Type: Article

DOI: 10.1387/EKAIA.17895 DIALNET GOOGLE SCHOLAR lock_openOpen access editor

More publications in: Ekaia: Euskal Herriko Unibertsitateko zientzi eta teknologi aldizkaria

Abstract

This study describes a new test configuration, based on an End Notched Flexure test configuration. A metallic roller is inserted between the two arms of the crack in order to get a mixed mode fracture. The external load application gives the mode II, and the opening of the crack is get by means of the inserted roller. Energy re-lease rate is the parameter used for analyzing interlaminar fracture. Each mode energy release rate is determined analytically and the results are compared with the ones obtained by finite element method. Experimental tests are performed with specimens of F593/T300 carbon/epoxy unidirectional composite. The procedure to determine crack length is checked, energy release rate curves are determined and a failure criterion is validated. Moreover, the values of GIc and GIIc are determined.