Finite cylinder-source model for energy pile heat exchangers: Effects of thermal storage and vertical temperature variations
- Bandos, T.V. 1
- Campos-Celador, Á. 1
- López-González, L.M. 2
- Sala-Lizarraga, J.M. 1
-
1
Universidad del País Vasco/Euskal Herriko Unibertsitatea
info
Universidad del País Vasco/Euskal Herriko Unibertsitatea
Lejona, España
-
2
Universidad de La Rioja
info
ISSN: 0360-5442
Ano de publicación: 2014
Volume: 78
Páxinas: 639-648
Tipo: Artigo
Outras publicacións en: Energy
Resumo
A mean integral solution to the FCS (finite cylindrical source) model for ground heat exchangers that takes into account the heat capacity inside the borehole or foundation and allows estimation of temperature field for an arbitrary borehole configuration is presented as a single integral. Approximate expressions for the average temperature over a wide range of time values are derived analytically in the vicinity of both sides of the finite cylindrical surface of heat source. Exact and approximate results for the mean temperature are compared to those calculated at the mid-depth from the exact solution of the same FCS model.